Last reviewed November 2026.
When Larimer County requires a deck permit
Larimer County's trigger is simpler than Fort Collins'. Its residential deck handout says a permit is required if either of two things is true: the deck is more than 30 inches above grade, or it serves as the main entry or exit to the structure. If neither is true, no building permit is required. Two things still apply either way: electrical work on the deck needs a county electrical permit, and the deck has to meet the Land Use Code's setback and floodplain rules, which county Planning (970-498-7679) can confirm.
Since January 1, 2026, permits in the unincorporated county are issued under the 2024 International Residential Code, with the county's 2025 Wildfire Resiliency Code alongside it.
What goes in the application
- A residential building permit application.
- Two full sets of plans to scale: plan view, cross sections and elevations showing footings, posts, beams, joists, ledger and connections.
- Three copies of a scaled site plan.
- A foundation plan stamped by a Colorado registered engineer if the location or design warrants it.

County deck construction rules
| Item | Rule |
|---|---|
| Lumber | Treated or naturally decay-resistant |
| Support | Piers or pads required |
| Footing depth, attached deck | At least 30 in below grade |
| X-bracing, attached deck | Surface 10 ft or more above grade at any point |
| X-bracing, detached deck | Surface 5 ft or more above grade at any point |
| Guard | Required over 30 in; 36 in minimum height; a 4 in sphere can't pass |
| Stair rise | 4 in minimum to 7-3/4 in maximum; variation 3/8 in or less |
| Stair run | 10 in minimum with 3/4 to 1-1/4 in nosing; 11 in without nosing |
| Handrail | More than 3 risers: continuous, graspable, 34 to 38 in above nosings |
Source: Larimer County Community Development, Residential Deck Information handout. Its footing and span tables are drawn at 40 psf ground snow for elevations of 5,500 ft or less.
Snow, frost and wind by elevation
The county's Structural Design Information sheet, updated January 2026, sets the minimum frost depth at 30 inches countywide and lists ground snow by elevation on the strength basis of ASCE 7-22: 55 psf up to 5,000 feet, 70 at 6,000, 80 at 6,500, 95 at 7,000 and 110 at 8,000. Basic wind speeds run from 115 to 225 mph by the county map. A home can be built to the code's prescriptive tables only where ground snow is 70 psf or less and wind is under 140 mph, which rules out the higher foothills. Those numbers are compared with each town's in the footing depth and snow load guide.
Height matters for bracing too: a second story deck 10 feet up needs X-bracing under the county handout.

The wildfire code in the unincorporated county
The county's 2025 Wildfire Resiliency Code, effective January 1, 2026, declares all of unincorporated Larimer County a wildland-urban interface area. Where its structure rules apply, a deck's walking surface has to be noncombustible, Class A rated, exterior fire-retardant-treated wood or ignition-resistant material, with composite allowed at Class B or better. What that means for a deck on an existing house is in the Larimer County wildfire code guide.